Insulating
Ducts for Efficiency |
|
|||||||||||||||||||||||||||||||||
|
Once the ducts have been installed, and the trunks and runs established,
it’s time to finish off the heating system by insulating the ducts. The
degree to which you insulate your ducts depends on local building codes
for energy efficiency, and whether the ducts are in conditioned or non-conditioned
areas. If a duct runs through an unheated crawl space, an unheated basement,
or garage, it must typically be insulated to R-4 or greater. If ducts
are long or poorly insulated, they often result in cool blows, or gusts
of air that have lost the desired temperature. In such a case, running
the heat can actually cool a room rather than heat it. The same can be
said for cool conditioned air, which must maintain its temperature or
fail to cool the room at the other end. |
|||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
How quickly the air moves through the ducts determines how well it will
hold its temperature. Well-sealed joints allow the ducts to carry air
at maximum capacity. Mastic is used because it will not degrade or shrink
away from the joint. Duct tape should not be used for this purpose, since
the tape degrades and decomposes, leaving the joint leaky and unprotected.
Once the ducts have been sealed, an insulating jacket is wrapped around the ducts and plenum. Like wall insulation, duct insulation is typically made of fiberglass. Insulators may use rigid insulation or faced fiberglass. The fiberglass surface faces in toward the duct, while the foil face protects the outside of the wrap, preventing conductive heat loss and protecting the fiberglass within. The insulation is applied in sheets that are cut to fit and seamed, usually along the sides. While some installers use foil tape for this purpose, most insist on attaching the pieces to one another with a staple gun. Staples are less likely to degrade or lose grip over time. |
||||||||||||||||||||||||||||||||||
Alternatives
Reflectix is a radiant barrier wrap designed to insulate against heat loss. Unlike traditional fiberglass insulation, Reflectix is made up of foil faces on the outside that hold bubble pack between layers of polyethylene for stability. Reflectix is designed to reflect 97 percent of radiant heat, keeping ducts cooler in the summer and warmer in the winter. While fiberglass insulation comes in two-inch-thick applications, Reflectix packs its seven layers in just 5/16-inch. As Jack Alexander, president of Atlanta Supply Co., of Atlanta, Georgia explains, Reflectix carries an R-5.6 value, a figure that would take two inches of insulated fiberglass to achieve. One of the drawbacks of fiberglass is its vulnerability to moisture. When pipes or ducts experience condensation, that moisture transmits to the fiberglass, forcing it to pack and lose its insulative value. Reflectix is fully foil faced and poly filled. It is installed with spacers every six to eight inches so that it sits away from the duct itself. This airspace prevents moisture buildup and discourages mold and mildew. There is no fiber to encourage nesting insects, and it cannot be pulled tight like fiberglass wrap. Again, once fiberglass wrap is pulled tight, packing occurs which interferes with the product’s ability to achieve full insulative value. To reach its stated R-value, fiberglass must be carefully installed, and kept dry. Because there are so many variables including the loft of the fiberglass insulation and the moisture, Alexander also believes that fiberglass alternatives are easier to install than traditional duct wraps. |
||||||||||||||||||||||||||||||||||